Sediments and Hydropower

Sediments at the Turbine: Risks, Solutions, Facts

Understand Risks. Develop Solutions.

How do sediments affect hydropower plants, and how can turbines and other hydraulic structures be protected?

Abrasion

Almost all turbine water contains sediment. Nevertheless, no abrasion is observed on most turbines. This is due to the typically low sediment content of the turbine water.

An increase in sediment concentration of a few percentage points does not change this. The maximum grain size of the transported sediment can be adjusted using our technical solutions for sediment transfer, thereby protecting the turbine from excessively large particles. Only in watercourses with particularly high sediment concentrations may the abrasion that naturally occurs in turbines be intensified. Even so, the additional turbine wear is significantly less costly than conventional sediment dredging operations. 

In addition, modern coating systems provide effective protection against abrasion. Where appropriate, sediment can also be routed around the dam and reintroduced into the river downstream of the hydropower plant.

Main shaft sealing

Here, too, it is important to note that virtually all water flowing through hydropower turbines contains sediment. However, the main shaft seal is particularly sensitive to particles. For this reason, most shaft seals are equipped with a clean-water flushing system that keeps the sealing surfaces free of sediment and other foreign particles. As a result, wear on the main shaft seal is entirely independent of the sediment concentration in the turbine water. Turbines that are not yet equipped with a clean-water flushing system can usually be retrofitted with this feature without difficulty.

Power plant intake

The hydropower plant intake screen is not obstructed, as the sediment settling zone can be positioned either downstream of the screen or downstream of the dam, depending on the sediment load and particle sizes.

Pump Turbines

In pumped-storage hydropower plants that use river impoundments as lower reservoirs, the sediment deposited in the upper reservoirs has already passed through the pump-turbines at least once.

Not all turbines respond in the same way.

Certain turbine types and operating conditions require particularly careful consideration of sediment loads – for example, as part of our studies and risk analyses.

Pelton Turbines

Due to the high water jet velocities involved, Pelton turbines require special consideration when assessing sediment loads.

Francis Turbines

Francis turbines operating under heads significantly greater than 200 m should also be given special consideration due to their sensitivity to particle loads.

Sediment Management for Your Facility

Would you like to know how sediment affects your hydropower plant and which technical solutions
are available for your specific site?